Benchmark Testing the ODEN CHF Loop to Columbia University HTRF
NURETH-14 - 2011 September 25-30


Presented at:
NURETH-14
2011 September 25-30
Location:
Toronto, Canada
Session Title:
F6-2 Integral Testing

Authors:
L. David Smith, III (Westinghouse Electric Co., LLC)
Anders Hallehn (Westinghouse Electric Sweden AB)
Abdelaziz Elmahdi (Westinghouse Electric Co., LLC)
Dong-Yuan Sheng (Westinghouse Electric Sweden AB)
Henrik Tejne (Westinghouse Electric Sweden AB)
  

Abstract

Westinghouse has designed and built ODEN, a new Critical Heat Flux (CHF) test loop for PWR applications. It is located at the Westinghouse Thermal-Hydraulic Test Facility in Västerås, Sweden. ODEN can accommodate full length (4.3 m) bundles, up to 6x6 rod arrays, up to 16 MW power, and accurately cover a wide range of PWR thermal-hydraulic conditions. Benchmark qualification CHF tests at ODEN were recently performed. Results indicate good agreement between CHF data from ODEN and data from HTRF. Repeatability (ODEN – ODEN) was also good. This paper presents the details of the comparative tests and the resulting data analyses.

Individual Conference-Paper Copies (Electronic Where Available):

  • For CNS members, the first 5 copies per calendar year are free, and additional copies are $10 each.
  • For non-members, the price is $25 for the first Conference-paper copy in a request, and $10 each for additional copies of papers in the same conference and in the same request.
  • Contact the CNS office to order reprints.