EFFECT OF HIGH FREQUENCY CONTENT OF UNIFORM HAZARD RESPONSE SPECTRA ON NUCLEAR POWER PLANT STRUCTURES, SYSTEMS AND COMPONENTS
35th Annual CNS Conference - 2015 May 31 - June 3


Presented at:
35th Annual CNS Conference
2015 May 31 - June 3
Location:
Saint John, Canada
Session Title:
2A2 - Safety and Security

Authors:
A. Usmani (Amec Foster Wheeler)
P. Baughman (Paul D. Baughman Consulting)
  

Abstract

 

The Uniform Hazard Spectrum (UHS) is developed from a probabilistic seismic hazard assessment and represents a response spectrum for which the amplitude at each frequency has a specified and uniform (equal) probability of exceedance. The high spectral acceleration at high frequencies in the UHS can result mainly from small non-damaging low energy earthquakes. Historically Canadian and U.S. nuclear power plants have been designed using the standard shape spectrum given in CSA N289.3 or USNRC Regulatory Guide 1.60, which have maximum spectral accelerations in the lower (2-10 Hz.) frequency range. The impact of the high frequency content of UHS on the nuclear power plant SSCs is required to be assessed.

 This paper briefly describes the methodologies used for screening and evaluation of the effects of UHS high frequency content on the nuclear power SSCs that have been designed using the CSA N289.3 standard shape spectrum.



 



Individual Conference-Paper Copies (Electronic Where Available):

  • For CNS members, the first 5 copies per calendar year are free, and additional copies are $10 each.
  • For non-members, the price is $25 for the first Conference-paper copy in a request, and $10 each for additional copies of papers in the same conference and in the same request.